| Library prep kit | Submit | Submission workflow | Quantity range (ng) | Volume required per prep (uL)* | Sample batch size** | Notes |
|---|---|---|---|---|---|---|
| Illumina Stranded mRNA | Total RNA | Illumina Stranded mRNA | 25-1000 | 25 | Any number | This kit supports various input mass; normalise where possible. |
| NEBNext Single cell / low input RNA Library Prep Kit for Illumina | Total RNA/cells | NEB low input RNA | 2pg - 200ng, or cell(s) | 8 | 24 | Please discuss your input requirements prior to submission. |
| Watchmaker PCR free | Genomics DNA | Watchmaker PCRfree | 1-500ng (300ng recommended) | 40 | 24 | Also suitable for FFPE extracted material using a modified protocol, plasmid DNA and long PCR products |
| Illumina DNA Prep with Enrichment | Genomic DNA | Illumina DNA Prep with Enrichment | 10-1000 | 30 | 16 | Also suitable for FFPE extracted material using a modified protocol. |
| ThruPLEX DNA-Seq | ChIP'ed DNA | Thruplex DNA Seq | 50pg - 50ng | 10 | 24 | |
| Watchmaker RNA with Polaris depletion | Total RNA | Other | 1-1000 | 18 | Any number | Also suitable for FFPE extracted material using a modified protocol. |
*Please provide an additional 15% volume per well.
We run a positive and negative control with every library prep.
Complete the Pool Information Fields
How to get a plate?
96 well barcoded plates and seals are available from the Genomics Core (Room 026).
Barcoded plates can also be obtained either from CRUK reception or via UMS for University users.
Plate Layout
- Please plate your samples in columns, as seen below. Please leave no gaps.
- You can only plate up to 94 samples per plate (2 wells are kept for the positive and negative controls).
Sample Input
Sample input needs to follow the guidelines from the table above. If you have a big gap between your highest and lowest concentration email Genomics Helpdesk for advice.
Randomisation
- If applicable, plate your samples according to the randomisation layout provided by your bioinformatic contact (discussed at your experimental design meeting).
- Best practice is to at least randomise your plate layout so sample groups are not co-located by row or column.
Sequencing requirements
- The bioinformatics contact on your project can confirm the quantity of sequence data required, read length, and recommended sequencer. This translates to the number of flowcell lanes required and run parameters.
Library Prep Submission Recommendations
- When eluting or diluting your sample, avoid using buffers containing high concentrations of EDTA and use DNAse as recommended in the kit manufacturer's instructions for RNA extraction.
- Quantify your nucleic acid using a fluorescent based method.
- When submitting DNA, we recommend performing QC to include size information using the Agilent Tape Station or equivalent.
- When submitting RNA, check the quality of each sample on the Bioanalyzer or Tapestation. If the RIN is <8, you can contact the Genomics Core for advice. A low quality score won't necessarily stop it being processed but can certainly lead to poor sequencing results, it is better to have this information if possible.
- For any ChIP-seq experiment, you will have performed the chromatin immunoprecipitation and just submit the ChIP'ed DNA.
- When submitting ChIP'ed DNA, check the fragmentation profile of your input(s) material. Please discuss with the Genomics Core if the fragments appear larger than 700bp.
- We do not specify a minimum quantity for a ChIP-seq experiment; please submit what you have. Always include at least one input control.
- Please upload QC data to the relevant project in our LIMS.
Library Prep Submission Recommendations
- This is thesubmission form for library prep specifically. Do not use this form to submit sequencing ready samples.
- There are different batch sizes depending on library prep, please see our price card or the table above for details.
- Researchers from within the CRUK-CI are strongly encouraged to attend an experimental design meeting prior to collecting samples for library prep submission.
- ContactCRIExperimentalDesign@cruk.cam.ac.uk to book a free experimental design session.
- If you have any questions, contact theGenomics Helpdesk.