Fill out the SLX identifier which is printed on the tube containing your library (SLX-xxxxx). SLX tubes can be obtained either from CRUK reception or via UMS for University users.
Enter the number of samples in the pool to be sequenced. If this is a pool without multiplexing, or a pool with in-line barcodes or custom indexing, set the pool size to 1.
Choose a sequencing workflow:
NovaSeqX : use this for direct NovaSeq sequencing requests.
NovaSeq X with MiSeq Nano QC: use this for NovaSeq sequencing requests which include a MiSeq Nano validation run of your library pool first; this provides an opportunity to adjust your pool if required before committing to the NovaSeq flowcell. This is highly recommended if you want to run multiple lanes of sequencing.
MiSeq: use this for all standard MiSeq v3 sequencing requests.
MiSeq Express: use this for MiSeq v3 sequencing if you want us to use your quantified concentration. We ask for samples to be submitted at 4nM and will not quantify your library ourselves.
MiSeq Nano: Use for MiSeq Nano requests.
MiSeq Nano Express: as for MiSeq Express but using a MiSeq Nano kit.
NextSeq 2000: use this for all standard NextSeq 2000 sequencing requests.
Select sequencing type from the drop-down menu: “Single Read” or “Paired End”.
Select read length from the drop-down menu or enter it manually if it is asymmetrical (e.g. 92+26).
Enter the number of lanes required. See table 2 below for expected yields for each flowcell type.
For NovaSeq and NextSeq 2000 runs, select the flowcell type.
The NextSeq 2000 flowcells are the “P” ones (P1, P2, P3); The NovaSeq X flowcells are the “B” ones (1.5B, 10B, 25B).
Leave this field empty for other sequencers.
Select library type from the drop-down menu.
Important: if submitting for the library types “Amplicon low diversity”, “Amplicon high diversity” or “Bisulphite” please read table 3 below regarding PhiX spike-in percentage.
If you are submitting for unspecified indexing where you will demultiplex yourself, you must specify the index lengths required for each index. _We cannot accept your library unless we have this information_.
Enter the average library length including insert and adapters (see point 4 of further information).
-
Select sample type, sample source and species from the drop down menus.
Complete billing information. This is critical for correct invoicing: please follow the popup instructions in the field. Only enter a PO number if applicable to your department or organisation. Leave PO number blank if it does not apply! Resist the temptation to put “N/A” or “None”: it will complicate your bills.
Enter any submission comments you think may be important to your submission (e.g., PhiX % you require spiked into the lane if it is non-standard).