Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Both sides previous revisionPrevious revision
Next revision
Previous revision
submission:10x_submissions [2026/04/10 12:57] – [Single Cell Submission] Johanna Barbierisubmission:10x_submissions [2026/11/27 09:09] (current) – [Single Cell Submission] Victoria Winfield
Line 5: Line 5:
  
 In the first instance, contact the single cell team to discuss details of the cells or nuclei submission to ensure they are aware of the experimental conditions and timelines.\\ In the first instance, contact the single cell team to discuss details of the cells or nuclei submission to ensure they are aware of the experimental conditions and timelines.\\
-[[singlecell@cruk.cam.ac.uk|Single cell team]]+[[singlecell@cruk.cam.ac.uk|Single cell team]]\\
 __**It is recommended for any single cell 10x Genomics project to consider a pilot experiment prior to a multi-sample project**__ __**It is recommended for any single cell 10x Genomics project to consider a pilot experiment prior to a multi-sample project**__
  
Line 12: Line 12:
  
 ^Workflow ^Kit used ^ Sample type ^ Volume loaded (µl) ^Max Target Concentration (cells/µl) ^Volume for User to Submit (µl) ^ # Cells Loaded ^ # Cells Recovered ^ Preferred Eppendorf ^ ^Workflow ^Kit used ^ Sample type ^ Volume loaded (µl) ^Max Target Concentration (cells/µl) ^Volume for User to Submit (µl) ^ # Cells Loaded ^ # Cells Recovered ^ Preferred Eppendorf ^
-|10x Single Cell 3GEX|Next GEM 3'v3.1|Cells/Nuclei| 43.2|370|55|16,000|10,000|1.5ml tubes| +|10x Single Cell 3' GEM-X|GEM-X 3'v4|Cells/Nuclei|36.6|683|45|25,000 |20,000  |1.5ml tubes| 
-|10x Single Cell 3GEMX|GEM-X 3'v4|Cells/Nuclei|36.6|683|45|25,000 |20,000  |1.5ml tubes| +|10x Single Cell 5' GEM-X|GEM-X 5'v3|Cells/Nuclei|37.5|667|45|25,000|20,000|1.5ml tubes| 
-|10x Single Cell 5GEX|Next GEM 5'v2|Cells/Nuclei|39.1|409|45|16,000|10,000|1.5ml tubes| +|10x Single Cell 3' GEM-X OCM 4-plex|GEM-X 3' OCM|Cells/Nuclei|9.6|860|15|8,250|5,000|1.5ml tubes| 
-|10x Single Cell 5GEMX|GEM-X 5'v3|Cells/Nuclei|37.5|667|45|25,000|20,000|1.5ml tubes| +|10x Single Cell 5' GEM-X OCM 4-plex|GEM-X 5' OCM|Cells/Nuclei|9.8|842|15|8,250|5,000|1.5ml tubes|
-|10x Single Cell 3GEMX OCM 4-plex|GEM-X 3' OCM|Cells/Nuclei|9.6|860|15|8,250|5,000|1.5ml tubes| +
-|10x Single Cell 5GEMX OCM 4-plex|GEM-X 5' OCM|Cells/Nuclei|9.8|842|15|8,250|5,000|1.5ml tubes|+
 |10x Multiome|Next GEM Multiome|Nuclei| 5|3200|10|16,000|10,000|0.2ml tubes| |10x Multiome|Next GEM Multiome|Nuclei| 5|3200|10|16,000|10,000|0.2ml tubes|
  
-And for the 10x Genomics GEMX Flex workflows - fixed samples (freshly fixed, formalin-fixed paraffin embedded (FFPE)):+And for the 10x Genomics GEM-X Flex workflows - fixed samples (freshly fixed, formalin-fixed paraffin embedded (FFPE)):
  
 ^Workflow ^Kit used ^ Sample type ^Max Number of Cells to Submit ^Max  # Cells Loaded ^ # Cells Recovered ^ Preferred Eppendorf ^ ^Workflow ^Kit used ^ Sample type ^Max Number of Cells to Submit ^Max  # Cells Loaded ^ # Cells Recovered ^ Preferred Eppendorf ^